-40%

Medical 12" Vital Signs Patient Monitor ECG NIBP RESP TEMP SPO2 Multi-parameter

$ 231.79

Availability: 100 in stock
  • Various interfaces:: standard , trend , oxyCRG , NIBP list , big front screen.
  • Item must be returned within: 30 Days
  • Technology: Digital
  • UPC: 190891578976
  • Screen Dimensions: 12 Inch
  • Function 1: Drug solubility calculation function
  • Battery: rechargeable lithium battery
  • Return shipping will be paid by: Seller
  • Feature 5: with a storage box
  • Condition: New
  • Feature 4: automatic sound and light alarm
  • Feature 6: Built-in lithium battery
  • Brand: Unbranded
  • Refund will be given as: Money Back
  • Intended Use/Discipline: Cardiology
  • Feature 3: Can be arbitrarily set the alarm limit
  • MPN: Does Not Apply
  • Uasage: Suitable for adult, pediatric and neonatal patient
  • Usage: Department of internal medicine
  • Monitor Parameters: PR
  • Standard configuration: SpO2, PR, NIBP, ECG, RESP, TEMP
  • Features: Battery Operated
  • Feature 2: Real-time S-T segment analysis
  • All returns accepted: Returns Accepted
  • Feaure 2: pace-maker detection.
  • Restocking Fee: No
  • Warranty: 24 months
  • function 2: Arrhythmia analysis function

    Description

    Portable Multi-parameter Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP.It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient.
    Features:
    12" high resolution color TFT LCD display.
    6 Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, PR.
    Can be arbitrarily set the alarm limit, automatic sound and light alarm.
    The back of the machine is designed with a storage box, which can put some accessories,convenient for doctors use.
    Drug solubility calculation function, Arrhythmia analysis function.
    Built-in lithium battery,AC and DC,can provide long-term monitoring after power failure.
    Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center,ICU,CCU.
    Specification:
    ECG
    Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
    Lead selection:I, II, III, avR, avL, avF, V,
    Waveform:2 ch
    Lead mode:3 Leads ( R, L, F or RA, LA, LL)
    Lead selection:I, II, III,
    Waveform:1 ch
    Gain:´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto
    HR and Alarm
    Range:
    Adult:15 ~ 300 bpm
    Neo/Ped:15 ~ 350 bpm
    Accuracy:± 1% or ± 1bpm,which great
    Resolution:1 bpm
    Sensitivity:> 200 (uV P-P)
    Differential Input Impedance:> 5 MΩ
    RESPARATION:
    Method:Impedance between R-F(RA-LL)
    Differential Input Impedance:>2.5 MΩ
    Measuring Impedance Range:0.3~5.0Ω
    Base line Impedance Range:0 – 2.5  KΩ
    Bandwidth:0.3 ~ 2.5 Hz
    Resp. Rate
    Measuring and Alarm Range
    Adult:0 ~ 120 rpm
    Neo/Ped:0 ~ 150 rpm
    Resolution:1 rpm
    Accuracy:±2 rpm
    Apean Alarm:10 ~ 40 S
    NIBP
    Method:Oscillometric
    Mode:Manual, Auto, STAT
    Measuring Interval in AUTO Mode
    1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
    Measuring Period in STAT Mode:5 Min
    Pulse Rate Range:40 ~ 240 bpm
    Alarm Type:SYS, DIA, MEAN
    Measuring and alarm range:
    Adult Mode
    SYS :40 ~ 270 mmHg
    DIA :10 ~ 215 mmHg
    MEAN:20 ~ 235 mmHg
    Pediatric Mode
    SYS:40 ~ 200 mmHg
    DIA:10 ~ 150 mmHg
    MEAN:20 ~ 165 mmHg
    Neonatal Mode
    SYS:40 ~ 135 mmHg
    DIA:10 ~ 100 mmHg
    MEAN:20 ~ 110 mmHg
    Overpressure Protection
    Adult Mode:297±3 mmHg
    Pediatric Mode:240±3 mmHg
    Neonatal Mode:147±3 mmHg
    SpO2
    Measuring Range:0 ~ 100 %
    Alarm Range:0 ~ 100 %
    Resolution:1 %
    Accuracy:
    70% ~ 100%  ±2 %
    0%  ~  69%  unspecified
    Actualization interval:about 1 Sec.
    Alarm Delay:10 Sec.
    Pulse Rate
    Measuring and Alarm Range:0~254bpm
    Resolution:1bpm
    Accuracy:±2bpm
    I.5TEMP measurement:
    Channel:1
    Measuring and Alarm Range:0 ~ 50 °C
    Resolution:0.1°C
    Accuracy:±0.1°C
    Actualization interval:about 1 Sec.
    Average Time Constant:< 10 Sec.
    Package List:
    1×Patient Monitor
    1×EKG Lead wire
    1×NIBP Cuff
    1×NIBP Extension Cable
    1×SpO2 Sensor
    1×Temp Sensor
    1×Ground Cable
    5×Electrode
    2×Fuse
    1
    ×User Manual(CD)
    Safe product:
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    ARTG NO: 278908 ARTG Number: 278908
    FDA Disclaimer:
    Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. (The seller name: Helen Zhang,City:Beijing State: Beijing Country: China Telephone number: 86-18730611603)
    This item has been cleaned and treated according to the manufacturer's instructions.
    The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013).
    Payment information:
    PayPal
    only.
    Please pay the money within 5 days after the auction ended.
    Shipping method:
    All items will be shipped  within 1 business days.
    More than 200$,Expedited shipping !!! About 3-5 business days!And It takes approximately 15-22 to remote Area .
    We are not Responsible for your Customs duty.
    Terms of sale
    Warranty:
    We guarantees new equipment for a period of
    24 months
    . Our company's obligation under this warranty is repairing or replacement.
    Return Policy :
    If you receive a defective item which you want to return, please contact us within 30 days from the day you receive the item. All return items must be returned with its original packaging and accessories.
    Feedback:
    Contact us first before leaving a negative, we will find a solution to meet your requirement and enhance the satisfaction.
    About us
    Quality First, Service Excellent, Global Trust!
    We are the manufacturer and distributor of medical equipments for more than 10 years. If you are interested in the distribution work, please feel free to contact us.
    We will reply to you within 24 hours. Please kindly wait for us.
    Contact us
    During the duty time ,we can give you a quick respond. If we are out of work ,please kindly be patient and considerable to give us a little more time ,not just leave the neutral or negative feedback without communication ,thank you for your cooperation !
    For more information, please feel free to contact us