-40%

Medical Monitor ICU CCU Vital Sign Patient Monitor ECG NIBP RESP TEMP SPO2 HR CE

$ 210.67

Availability: 84 in stock
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Brand: Carejoy
  • EAN: Does not apply
  • Country/Region of Manufacture: China
  • UPC: Does not apply
  • Condition: New
  • Certification: FDA CE
  • Monitor Parameters: ECG
  • Display: 8 inch color display
  • Intended Use/Discipline: Medical Laboratory
  • Bundle Listing: Yes
  • Standard configuration: ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Warranty: 2 year
  • Features: Portable
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • MPN: Does Not Apply
  • Application: NICU, ICU, OR, CCU
  • Type: Patient Monitor
  • Model: RPM-9000D3
  • Support: Support use in NICU, ICU, OR, CCU or normal patient room

    Description

    Description:
    Dental Oral
    implant
    monitor can be used in oral implant surgery. It can monitor and measure human body's vital signs in real time for patients, especially patients with cardiovascular and cerebrovascular diseases and diabetes, and monitor the changes of life signs in real time, and provide basis for oral implant.
    Features:
    High brightness and high resolution display 8 inch color LCD screen ,more comfortable glare
    7-Channel ECG Waveform display,5 minutes ECG waveform playback, automatic detection of ST segment
    384 hours trend data memory for all the parameters and dynamic waveform capture
    Can be arbitrarily set the alarm limit, automatic sound and light alarm
    Anti-movement, anti-defibrillation, anti electrosurgical interference
    Remote central monitoring network interface
    Drug solubility calculation function, Arrhythmia analysis function
    Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure
    Widely used in the Department of internal medicine,
    D
    ntal practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.
    Standard configuration:
    ECG, NIBP, SPO2, TEMP, RESP,
    Technical parameters:
    ECG Measurement

    Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed
    Gains options:   × 1, × 2, × 4, and × 0.5 four trenches
    Frequency:
    diagnosis  0.05 ~ 130Hz
    Monitoring  0.5 ~ 40Hz
    Operation 1~ 20Hz
    Common-mode signal inhibition:
    diagnosis  > 90 dB
    Monitoring  > 100 dB
    Operation > 100 dB
    Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.
    HR range:
    Adult :15

    300bpm
    Infants / children: 15

    350 bpm
    HR Accuracy: ± 1 bpm
    Precision calibration signal: 1mv(peak, ± 5% accuracy)
    ST Detection: measurement range (-2.0mV

    +2.0mV)
    Baseline recovery time: < 3 seconds after defibrillation
    Alarm: Sound and Light
    Preset heart rate range: (Alarm over preset numerical)
    Ceiling:40

    255 bpm adjustable
    Threshold: 20

    160 bpm adjustable
    RESP Breath:
    Breathing frequency range:
    Adult : 7

    120 brPM
    Infants / children:7

    150 brPM
    Accuracy:± 2brpm
    Gains options: × 1, × 2, × 4, and × 0.5 four trenches
    Alarm: Sound and Light
    Alarm range: (numerical preset alarm over)
    Ceiling:       10

    100 bpm adjustable
    Threshold:     0

    99 bpm adjustable
    NIBP measurement:
    Technology: Oscillometric
    Mode: Manual / automatic / continuous
    Measurement units: mmHg / kpa
    Protection: Double security protection
    Scope: Pressure Cuffs 0-250 mmHg
    Overvoltage protection: Double safety protection
    Adult Pattern

    300 mmHg
    Children Pattern

    240 mmHg
    Newborn Pattern

    150 mmHg
    Blood pressure measuring range:
    Adult
    Systolic blood pressure: 40

    270 mmHg
    Diastolic blood pressure: 10

    215 mmHg
    Pressure on the average: 20

    235 mmHg
    Children
    Systolic blood pressure: 40

    200 mmHg
    Diastolic blood pressure: 10

    150 mmHg
    Pressure on the average: 20

    165 mmHg
    Newborn
    Systolic blood pressure: 40

    135 mmHg
    Diastolic blood pressure: 10

    100 mmHg
    Pressure on the average: 20

    110 mmHg
    The accuracy of blood pressure:The maximum average error amp 5mmHg; maximum standard deviation 8mmHg
    Alarm: Sound and Light
    Preset range: report (Numerical exceed preset alarm)
    Systolic blood pressure maximum: 40

    250 mmHg adjustable
    Threshold: 10

    220 mmHg adjustable
    Diastolic blood pressure ceiling: 20

    250 mmHg adjustable
    Minimum standards: 10

    220 mmHg adjustable
    Spo2 measurement
    Range: 70

    00%:
    ±
    2DIGIT  0

    69%

    Not defined
    Resolution: 1%
    Pulse frequency: 20

    300 times / min
    Alarm: Sound and Light
    Preset range: report (Alarm over preset numerical)
    Ceiling: 20%

    100% adjustable
    Threshold: 10%

    99% adjustable
    TEMP measurement:
    Technology: thermostat temperature probe
    Measuring range: 0
    °
    C

    45
    °
    C
    Temperature resolution: 0.1%
    Accuracy: ± 1°C
    Response Time: 1s
    Alarm: Sound and Light
    Preset range: report (numerical preset alarm over)
    Maximum: 20.1
    °
    C

    45
    °
    C adjustable
    Threshold: 20
    °
    C

    44.9
    °
    C Adjustable
    Power:
    AC power supply: AC 220V, 50Hz. 1A maximum current
    Temperature: 5

    40
    °
    C
    Storage temperature: -20
    °
    C

    40
    °
    C
    Working humidity:

    85% relative humidity, non-condensing
    Humidity storage:

    95% relative humidity, non-condensing
    Altitude: 86

    4106kpa feet (working condition)
    Whole Power: not more than 70VA
    Payment
    We only accept payment via PayPal.
    FDA Disclaimer:
    Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    Shipping
    1.
    US Stock
    items Shipping Service UPS 3-5 BUSINESS DAYS (weekend and festival not included) from our warehouse in the US,
    only to United-States.
    China Stock
    items will be shipped by epacket
    or Airmail post within 1 business days.
    2.We are not Responsible for your Customs duty.
    3.
    We don't add taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties). Please find out as much as you can about your import taxes in your own country before bidding the item. You need to pay for the import duties in case that occurred for certain goods
    .
    About US
    Our working time: Monday - Friday   9:00 AM - 5:30PM (Beijing) we
    ship the package from Monday to Saturdays.
    Seller Name: Amy
    Country: China
    City: Beijing
    Phone No.:86-13578942564
    About Warranty:
    We guarantees new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective.
    Return Policy

    1.If you receive a defective item which you want to return, please contact us within 2 days from the day you receive the item.
    2.All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.
    3.We will refund the money to you when we get the return items. Or replace item for you free of charge.